Anatomy of the birdsmouth
The birdsmouth is a notch near the foot of a rafter. The seat cut is level and sits on the top plate; the heel cut is plumb and bears against the outside face of the wall. Everything above the inside corner of the notch, measured plumb from the outside of the wall to the top edge of the rafter, is the height above plate, or HAP. The material left below the notch, measured square to the rafter edge, is what carries the reaction into the wall.
- Pitch angle
- φ = atan(rise / 12)
- Seat length on the plate
- s = min(plate width, (D / 4) / sin φ)
- Heel cut height
- h = s · tan φ
- Notch depth square to the edge
- d = s · sin φ
- Height above plate
- HAP = D / cos φ − h
D is the actual depth of the rafter, 7-1/4" for a 2×8, never the nominal 8". The seat is as long as the plate is wide unless that would make the notch deeper than the code allows, in which case the seat is shortened and the rafter bears on part of the plate.
The three IRC R802 rules
The rafter sections did not move in the 2024 renumbering, so the same citations apply to both the 2024 and 2021 IRC.
| Rule | Requirement | Applies to |
|---|---|---|
| R802.6 bearing | ≥ 1-1/2" on wood or metal; ≥ 3" on masonry or concrete | Every rafter end |
| R802.7.1 end notch | Notch depth ≤ D/4 of the actual rafter depth | Sawn-lumber rafters notched at the end |
| R802.7.1.1 cantilever | Remaining depth ≥ 3-1/2" and cantilever ≤ 24" | Notches on cantilevered (overhang) portions |
| R802.7.2 engineered | Notching only as the manufacturer permits | I-joists, LVL, glulam, trusses |
In practice, the D/4 cap governs on steep roofs and the plate width governs on shallow ones. The cantilever exception matters when a rafter with an overhang has a deep seat cut: the notch may exceed D/4 if at least 3-1/2" of rafter remains above it and the overhang beyond the wall is no more than 24" measured along the rafter.
Worked numbers: 2×8 rafters on a 2×6 wall
A 2×8 rafter has D = 7-1/4", so the end-notch limit is 1-13/16" (1.8125"). The 2×6 wall plate is 5-1/2" wide. Running the formulas at four pitches shows where each rule takes over.
| Pitch | φ | Seat s | Heel h | Notch d | HAP | Governs |
|---|---|---|---|---|---|---|
| 4/12 | 18.43° | 5.500" | 1.833" | 1.739" | 5.809" | Plate width |
| 6/12 | 26.57° | 4.053" | 2.026" | 1.813" | 6.079" | D/4 |
| 8/12 | 33.69° | 3.268" | 2.178" | 1.813" | 6.535" | D/4 |
| 12/12 | 45.00° | 2.563" | 2.563" | 1.813" | 7.690" | D/4 |
Every seat in the table is longer than 1-1/2", so R802.6 bearing passes on a wood plate. At 12/12 the rafter bears on less than half of the plate; that is legal, and it is the price of keeping 75% of the rafter depth at the wall.
Laying out with a fixed HAP
On a roof with any variation in plate height or rafter depth, frame to a constant HAP rather than a constant seat length. Choose the HAP once from the table, then on every common rafter measure that distance down the plumb line from the top edge and draw the seat cut from there. Rafters with a slightly deeper or shallower crown still put their top edges in the same plane, which is what the sheathing sees.
- Draw the ridge-face plumb cut and step off the line to ridge face from it along the top edge. Half the ridge is already deducted from that number.
- Draw the plumb heel line at the outside of the wall.
- Measure the HAP down the heel line from the top edge and draw the level seat line from that point.
- Check that the notch depth, square to the edge, is within D/4 (or the cantilever exception) before cutting.
- Cut the first rafter, test it at both ends of the building, then use it as the pattern.
Hip rafters and the 16.97" unit run
On a hip roof with equal pitches meeting at a 90° corner, the hip runs diagonally across the plan. For every 12" of common run, the hip travels the diagonal of a 12" square, 12√2 = 16.97". The hip’s unit rise is the same as the commons’, so its pitch is rise per 16.97 rather than per 12, and its length per foot of common run is the diagonal of rise and 16.97.
- Hip unit run
- 12 · √2 = 16.97"
- Hip length per foot of common run
- √(16.97² + rise²)
- Hip factor
- √(2 + (rise / 12)²)
- Common factor
- √(1 + (rise / 12)²)
| Pitch | Common length | Hip length | Hip factor |
|---|---|---|---|
| 4/12 | 12.65" | 17.44" | 1.453 |
| 6/12 | 13.42" | 18.00" | 1.500 |
| 8/12 | 14.42" | 18.76" | 1.564 |
| 12/12 | 16.97" | 20.78" | 1.732 |
A 6/12 hip over a 10' common run (120") is 120 × 1.5 = 180" of line length before shortening, against 134.16" for the common. Shorten the hip at the ridge to suit the framing detail (typically half the 45° thickness of the ridge or the common it frames against), and either back the hip (bevel both top edges) or drop it so its top edges land in the roof planes. For a 1-1/2" hip at 6/12 the drop is 0.75 × 6 ÷ 16.97 ≈ 1/4".
Jack rafters and the common difference
Jack rafters run from the plate to the hip at the same pitch as the commons, each one shorter than the last by a fixed amount, the common difference. Because jacks are laid out on the same on-center spacing as the commons, the difference is just that spacing measured along the slope.
- Common difference
- Δ = spacing / cos φ
- Side (cheek) cut on the jack
- atan(cos φ), measured from square
| Pitch | 16" on center | 24" on center |
|---|---|---|
| 4/12 | 16.87" | 25.30" |
| 6/12 | 17.89" | 26.83" |
| 8/12 | 19.23" | 28.84" |
| 12/12 | 22.63" | 33.94" |
Lay out the longest jack as a common rafter, shorten it at the hip by half the hip’s 45° thickness (1-1/16" level for a 1-1/2" hip, converted along the slope by dividing by cos φ), then subtract one common difference for each jack toward the corner. Cut jacks in left and right pairs; the cheek cut is mirrored on each side of the hip.